Name | Cooley Renal Artery Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Steknor International |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Renal Artery Clamp
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25″, 7.5″ and 10.75″ to accommodate a number of different surgical approaches and surgeon preferences.
SKU:
SN-59845
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Renal Artery Clamp” Cancel reply
Shipping & Delivery
Related products
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Patent Ductus Clamp – 6 1/4″
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Exclusion Clamp
Exclusion Clamp
s shaped, curved jaws 8.5 cm, 7-1/4" (18.5 cm)
Aortic Exclusion Clamp are ideally made for use in cardiothoracic surgical procedures in which there is a need to exclude a certain portion of the aorta. The unique "S" shaped curvature of the jaws makes it contoured to fit the unique curvature and shapes necessary of atraumatic clamping of vessels. Although this instrument could have a wide application on other vessels it is designed for use in clamping of the aorta. This instrument is comprised of premium German operating-room grade stainless steel.
Cooley Aorta Clamp
Cooley Aorta Clamp
Cooley Aorta Clamp is ideally suited for some cardiothoracic surgeries. This clamp is designed with a slight U-shaped hook shape to make a perfect tool for manipulation and clamping of the aorta. Additionally, these clamps are well suited for use in sectioning a specific portion of the aorta because they are created for easy handle a firm grip without causing any injury or damage to the vessel itself. This instrument is available in two different jaw lengths to make it suitable for use in a wide number of patients and surgeon preferences.
Cooley Neonatal Clamp
Cooley Neonatal Clamp
5" (12.5 cm)
Cooley Neonatal Clamp is the ideal tool for use in surgical procedures for newborn children. This clamp is build sturdily but made small enough to clamp the delicate vessels of a newborn child. This instrument is particularly well suited due to its ability to maintain a hold on the vessel without causing tears or rip on the delicate vessel walls of the newborn. Additionally, this clamp is available in a straight profile, spoon jawed, anastomosis clamp, carotid clamp or angled shank and straight jaws or curved shanks and angled jaws.
Calman Carotid Clamp
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4" (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
Beck Miniature Aorta Clamp – Titanium
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cooley Tangential Occlusion Clamp
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4" (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.
Reviews
There are no reviews yet.