Name | Cooley Anastomosis Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Steknor International |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2″ (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
SKU:
SN-51821
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Anastomosis Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Iliac Clamp
Cooley Iliac Clamp
Cooley Iliac Clamp allows for exquisite control of blood flow through large arteries during a number of orthopedic and cardiac procedures, or whenever temporary occlusion of the iliac vasculature is desired. Renowned for its ease of use, Cooley Iliac Clamp is designed for the application of variable pressures on the Iliac artery to prevent intrusive blood flow. It provides for a strong, secure and adjustable grip which can be used for closure of vasculature or secure clamping of soft tissue. The jaws are set at a slight angle so as to allow maneuverability while still maintaining pressure and control when clamping the intended area. This clamp features straight jaws, handles angled at 45 degrees and is available in two different jaws sizes.
Cooley Renal Artery Clamp
Cooley Renal Artery Clamp
Cooley Renal Artery clamp is ideally suited for use in cardiothoracic surgeries. The slightly curved shanks and angled jaws make this clamp perfect for its ideal use which is as a renal clamp to fully or partially cause occlusion of the renal vessels. These jaws are atraumatic thus reducing injury and stress to the vessel walls while still remaining firmly in their affixed location. This instrument is available in three sizes: 7.25", 7.5" and 10.75" to accommodate a number of different surgical approaches and surgeon preferences.
Cooley Patent Ductus Clamp – 6 1/4″
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Occlusion Clamp
Cooley Occlusion Clamp
curved jaws, jaws 3.6 cm long
Cooley Occlusion Clamp is designed for use in cardiothoracic surgical procedures. This clamp can be used to clamp vessels to reduce or stop blood flow to prevent the patient from losing an excessive amount of blood. The jaws allow for firm grasp of the vessels but with reduced risk of crushing or bruising to the vessel wall. Additionally, this clamp features curved shanks and jaws giving them a contour more suitable for use in vascular surgical procedures. This instrument is available in two different lengths to accommodate different vessel sizes and positions.
Beck Miniature Aorta Clamp – Stainless
Beck Miniature Aorta Clamp - Stainless
straight shanks, 6-3/4" (17.0 cm), debakey jaws, stainless
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Bailey Aorta Clamp
Bailey Aorta Clamp
angled shanks
Bailey Aorta Clamp are designed for use in cardiothoracic surgical procedures. This clamp is ideal for use when there is a surgical maneuver that requires exclusion of a specific portion of the vessel. The unique design of this clamp with the slightly angled shanks allows for this clamp to effectively reach and clamp off the aorta when other instruments may not be able to. Additionally, this instrument is available in three different jaw sizes: extra small, small and large making it well suited for a number of different vessel sizes but also in different levels of blood flow restriction.
Cooley Acutely Curved Clamp
Cooley Acutely Curved Clamp
angled shanks, jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Acutely Curved Clamp is designed for use in cardiothoracic surgeries. This instrument is designed to clamp vessels to reduce or completely block blood flow during surgery to allow the procedure to continue in a certain anatomical location where the blood is no longer able to flow through. These clamps feature an angled shanks as well as jaws calibrate at 5 mm intervals. Additionally, this instrument is available in three sizes: small, medium and large to accommodate a variety of patient sizes and a the wide variety of vessels that this clamp can be used on.
Reviews
There are no reviews yet.