Name | Maltzman-Fenzl Lens Manipulating Hook |
Lead Time | Lead time advised within 48 hours of order placement. |
Competitor | ;OP0923851;OP0923-851;601311;60-1311;6013-11;601312;60-1312;K3-5532;K35532;6013-12;6013-11_6013-12; |
Specialty | Ophthalmology-Hooks & Manipulators |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Steknor International |
Sterility | Non-Sterile |
Usage | Reusable |
Maltzman-Fenzl Lens Manipulating Hook
0.15 mm v-shaped tip, 4-3/4″ (12.0 cm)Â Maltzman-Fenzl Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The tip contains 2 prongs designed to cup the lens in a variety of positions. Both angled and straight models are available with the hook depending on surgical preference.
SKU:
SN-15822
Category: Hooks &Manipulators
Description
Reviews (0)
Be the first to review “Maltzman-Fenzl Lens Manipulating Hook” Cancel reply
Shipping & Delivery
Related products
Gass Retinal Detachment Hook
5-3/4" (14.5 cm)Â Gass Retinal Detachment Hook is a multipurpose tool used for procedures involving the retina and extraoccular muscles. The rounded hook may be used to examine the delicate retinal tissue for manipulation following detachment. IN addition, the wide tip is handy for the lifting of extraocular muscles for the passing of sutures.
Shepard Iris Hook
1.0 mm, blunt, 4-7/8" (12.4 cm)Â Shepard Iris Hook is a commonly used tool in cataract surgeries. The hook is used to retract a portion of the iris tissue to gain access to the lens capsule. Often, multiple hooks are used at different positions around the iris and anchored, providing adequate visualization for lens removal. The hook features a blunt tip to minimize extraneous tissue damage.
Double Fixation Hook
5-1/4" (13.5 cm)Â Double Fixation Hook is a useful tool in ophthalmic and occuloplastic procedures. The instrument may be used to atraumatically fix the lid or other skin flaps for manipulation of deeper tissues. Two different hook widths are available depending on surgical preference and patient variation.
Knolle Iris Hook
0.5 mm hook, 4-7/8" (12.4 cm)Â Knolle Iris Hook is a commonly used tool in cataract surgeries. The hook is used to retract a portion of the iris tissue to gain access to the lens capsule. Often, multiple hooks are used at different positions around the iris and anchored, providing adequate visualization for lens removal. The Knolle hook has a slender tip for more selective retraction while featuring a serrated handle for an improved grip.
Hirschman Iris Hook
0.75 mm hook, angled, 4-3/4" (12.0 cm)Â Hirschman Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.75mm hook provides fine control while retracting only a selected portion of iris tissue. A blunted tip assures minimal tissue damage to the surrounding globe.
Jaffe-Maltzman Lens Manipulating Hook
0.15 mm v-shaped angled tip, flat handle, 4-3/4" (12.0 cm)Â Jaffe-Maltzman Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook features a "V" shaped design for adjustable traction and stability while manipulating the lens into a desired position. The flat handle provides a sure grip during the operation.
Green Strabismus Hook
flat handle, 5-1/8" (13.0 cm)Â Green Strabismus hook is a commonly used instrument in performing procedures involving the ocular muscles. The hook can be used to elevate the muscle tissue for dissection and reattachment. The toe of the hook is designed to press against the sclera and "ski" along the surface until the full muscle width has been discerned.
Sheets Iris Hook
0.3 mm hook w/ guard, 5-1/8" (13.0 cm)Â Sheets Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.3mm hook provides extra fine control in retracting only the desired portion of iris. In addition, the hook comes available with a guard to protect from damaging surrounding tissue.