Name | Gass Retinal Detachment Hook |
Lead Time | Lead time advised within 48 hours of order placement. |
Competitor | ;MA635R;H1903;H-1903;OP0924701;OP0924-701;350372;350-372;E4991;604991;60-4991;6049-91; |
Specialty | Ophthalmology-Hooks & Manipulators |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Steknor International |
Sterility | Non-Sterile |
Usage | Reusable |
Gass Retinal Detachment Hook
5-3/4″ (14.5 cm)Â Gass Retinal Detachment Hook is a multipurpose tool used for procedures involving the retina and extraoccular muscles. The rounded hook may be used to examine the delicate retinal tissue for manipulation following detachment. IN addition, the wide tip is handy for the lifting of extraocular muscles for the passing of sutures.
SKU:
NHS-05-1185
Category: Hooks &Manipulators
Description
Reviews (0)
Be the first to review “Gass Retinal Detachment Hook” Cancel reply
Shipping & Delivery
Related products
Fenzel Lens Manipulator
10.0 mm shaft w/ 0.2 mm t-shaped hook, 4-3/4" (12.0 cm)Â Fenzel Lens Manipulator is a commonly used tool during cataract procedures. The manipulator features an additional stabilizing bar on the tip to aid in controlling the lens to an appropriate position for extraction. Both straight and angled models are available depending on surgical preference.
Maltzman-Fenzl Lens Manipulating Hook
0.15 mm v-shaped tip, 4-3/4" (12.0 cm)Â Maltzman-Fenzl Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The tip contains 2 prongs designed to cup the lens in a variety of positions. Both angled and straight models are available with the hook depending on surgical preference.
Kuglen Iris Hook & Lens Manipulator – Push-Pull Pattern
push-pull pattern, 4-1/2" (11.5 cm)Â Kuglen Iris Hook & Lens Manipulator is a multipurpose tool used in a variety of cataract procedures. The rounded button end is delicate enough to retract iris tissue to expose the anterior capsule of the lens. In addition, the instrument can be used to maneuver the lens into an ideal position for retraction. Both straight and angled models are available depending on physician preference.
Hirschman Iris Hook
0.75 mm hook, angled, 4-3/4" (12.0 cm)Â Hirschman Iris Hook is a commonly used tool during cataract procedures and operations needing access to the lens capsule. The 0.75mm hook provides fine control while retracting only a selected portion of iris tissue. A blunted tip assures minimal tissue damage to the surrounding globe.
Knolle Iris Hook
0.5 mm hook, 4-7/8" (12.4 cm)Â Knolle Iris Hook is a commonly used tool in cataract surgeries. The hook is used to retract a portion of the iris tissue to gain access to the lens capsule. Often, multiple hooks are used at different positions around the iris and anchored, providing adequate visualization for lens removal. The Knolle hook has a slender tip for more selective retraction while featuring a serrated handle for an improved grip.
Jameson Muscle Hook
5-1/8" (13.0 cm)Â Jameson Muscle Hook is a useful tool in performing strabismus or other ophthalmologic procedures involving the ocular muscles. The hook can be used to elevate the muscle tissue for dissection and reattachment. The rounded tip ensures atraumatic entrance underneath the desired muscle. Two different sizes are available with the hook depending on surgical preference.
Lewicky Lens Manipulating Hook
9.0 mm shaft, 90 degrees angled 2.0 mm tip, curved, 4-1/2" (11.5 cm)Â Lewicky Lens Manipulating Hook is a commonly used tool during cataract procedures. The hook is used to manipulate the opacified native lens during a phacoemulsification procedure. The extended length of the hook combined with the angled tip minimizes surgical obstruction during the procedure.
Maloney No-Hole Iol Manipulator
tear drop shape tip w/ post, 4-3/4" (12.0 cm)Â Maloney No-Hole IOL Manipulator is a useful tool for cataract procedures. The tear-drop shaped tip is ideal for manipulating the lens implant without risk of damaging or scratching. The extended working length allows the surgeon to maneuver the implant into the space desired.
Reviews
There are no reviews yet.