Name | Cooley Caval Occlusion Forceps |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Steknor International |
Sterility | Non-Sterile |
Usage | Reusable |
Cooley Caval Occlusion Forceps
Cooley Caval Occlusion Forceps
8-1/4″ (21.0 cm)
Cooley Caval Occlusion Forceps are specially designed vascular clamps for use in cardiothoracic surgical procedures. This instrument is designed with ring handles for ease in maneuvering and opening and closing and also a ratcheting mechanism to hold the forceps at a particular tightness. The most unique feature of these forceps is that each jaw features a half circle projection outwards which when the jaw is brought together forms a complete circular opening as well as the fact that the entire instrument is formed in a crescent type shape. This instrument is available with a number of different diameters to the opening in the jaws in 2 fr. Increments from 24 – 40 fr.
SKU:
SN-36813
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Cooley Caval Occlusion Forceps” Cancel reply
Shipping & Delivery
Related products
Beck Miniature Aorta Clamp – Titanium
Titanium
straight shanks, 6-3/4" (17.0 cm), debakey jaws, titanium
Beck Miniature Aorta clamp is designed for use in cardiothoracic surgeries. This miniature aorta clamp is ideally suited for use in neonatal or pediatric patients who have vessels that are too small to be handled by traditional sized instruments. This instrument can be used to clamp the aorta to occlude blood flow and prevent excessive bleeding during surgery. Additionally, this clamp is available with either DeBakey jaws or titanium jaws.
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Cooley Auricular Appendage Forceps
Cooley Auricular Appendage Forceps
1-5/8" x 3/8" (4.1 cm x 1.0 cm) jaws, 10" (25.4 cm)
Cooley Auricular Appendage Forceps are specially designed for use in cardiothoracic surgical procedures. These forceps have a wide application but are particularly well suited for use in manipulating auricular appendages. Each auricle leads into its respective atrium and thus this instrument is of use in surgical procedures that require access to the atria. The scissor handle grip allows for ease in grasping and manipulating this tool.
Cooley Patent Ductus Clamp – 6 1/4″
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Castaneda Clamp
Castaneda Clamp
curved shanks, long thin jaw, calibrated jaws, horizontal serrations, 6" (15.0 cm)
Cataneda Clamp is a versatile tool made for use in cardiothoracic surgical procedures for newborn babies. This clamps are designed for neonatal use and as much are much smaller than their traditional counterpart but are equally effective. This multipurpose clamp is designed with curved shanks as well as long thing calibrated jaws coupled with horizontal serrations. Additionally, this instrument is available at varying angles and as a multi purpose or partially occluding clamp making it easy to find a perfect fit for any surgical procedure.
Cooley Cardiovascular Clamp
Cooley Cardiovascular Clamp
2" (5.1 cm) curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is an ideal tool for use in cardiothoracic surgical procedures that require clamping of vessels to prevent excessive bleeding. This instrument is designed with two inch curved jaws that allow for stable closure of vessel while maintaining gentle enough pressure on the vessel wall to prevent damage or tearing. Additionally, this clamp features a ratcheting mechanisms to keep the clamp locked in place during surgery.
Cherry Supraceliac Clamp
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Calman Carotid Clamp
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4" (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
Reviews