Name | Calman Carotid Clamp |
Lead Time | Lead time advised within 48 hours of order placement. |
Specialty | Cardiothoracic-Cardiovascular Clamps |
Material Finish | Stainless Steel |
Grade | Premium Operating Room |
Units of Measurement | Each |
Manufacturer | Steknor International |
Sterility | Non-Sterile |
Usage | Reusable |
Calman Carotid Clamp
Calman Carotid Clamp
angled shanks, long thin jaw, 25.0 mm, 4-1/4″ (11.0 cm)
Calman Carotid Clamp is ideally suited for use in cardiothoracic surgical procedures specifically in surgeries that require clamping of the carotid vessels. This clamp feature angled shanks to increase the easy of access to the vessels as well as having a long thing jaw that allows it to move between deeper layers of tissue without displacing anything or injuring other organs of vasculature. This clamp is strong enough to provide the occluding force necessary but also is gentle enough to keep the carotid walls intact with minimal injury or bruising.
SKU:
NHS-04-1009
Category: Cardiovascular Clamps
Description
Reviews (0)
Be the first to review “Calman Carotid Clamp” Cancel reply
Shipping & Delivery
Related products
Cooley Cardiovascular Clamp
Cooley Cardiovascular Clamp
2" (5.1 cm) curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is an ideal tool for use in cardiothoracic surgical procedures that require clamping of vessels to prevent excessive bleeding. This instrument is designed with two inch curved jaws that allow for stable closure of vessel while maintaining gentle enough pressure on the vessel wall to prevent damage or tearing. Additionally, this clamp features a ratcheting mechanisms to keep the clamp locked in place during surgery.
Cherry Supraceliac Clamp
Cherry Supraceliac Clamp
shanks curved 60 degrees, debakey 2x3 teeth, jaws 5-3/4", curved, 12-1/2" (31.0 cm)
Cheery Supraceliac Clamp is created to be of optimal use in cardiothoracic surgical procedures. This instrument is especially useful aortic aneurysm repairs of the abdominal and thoracic aorta particularly this clamp can be used in accessing the portion of the aorta that is found superior to the celiac artery. Curved shanks coupled with a 60 degree angle and DeBakey teeth allow this clamp to access some deeper vessel structures without damaging the vessel walls or the surrounding tissue.
Cooley Patent Ductus Clamp – 6 1/4″
Cooley Patent Ductus Clamp - 6 1/4"
jaws calibrated at 5.0 mm intervals, 6-1/4" (16.0 cm)
Cooley Patent Ductus clamp is well suited for use in cardiothoracic surgical procedures. Specifically this clamp is designed for use in surgical procedures to repair a patent ductus. The jaws of this clamp are calibrated at 5 mm intervals and are designed for a firm surgical grip upon the vessels but is delicate enough to prevent any bruising or tears to the vessels walls themselves. This instrument is available with either straight or angular shanks making it possible to select the best fit possible for the procedure at hand.
Cooley Tangential Occlusion Clamp
Cooley Tangential Occlusion Clamp
double angled jaws calibrated at 5.0 mm intervals, 7-3/4" (19.5 cm)
Cooley Tangential Occlusion Clamp is uniquely designed to clamp vessels in a way that reduces blood flow without completely stopping it in cardiothoracic surgical procedures. This clamp can be best used when doing procedures such as side-by-side anastomosis that required some blood flow. Additionally, this instrument features double angled jaws that are calibrated at 5 mm intervals making it possible to make accurate measurements during the procedure.
Cooley Aortic Aneurysm Clamp
Cooley Aortic Aneurysm Clamp
slightly curved jaws, jaws 7.6 cm, 10-3/4" (27.3 cm)
Cooley Aortic Aneurysm Clamp is made to be used cardiothoracic procedures that require clamping of the aorta, specifically at or around the site of aneurysm. This clamp can be used to in temporary occlusion of the aorta to resect fusiform aneurysms as well as provide additional support and stability in aortic grafting procedures. The slightly curved jaws gives this clamp the ability to contour to and seamlessly move through the surgical field causing the least amount of trauma to the aorta itself and surrounding tissue.
Cooley Cardiovascular Clamp – Fully-Curved
Fully-Curved
for temporary occulation of the iliac artery, 2-3/4" (7.0 cm) fully-curved jaws, 10-3/4" (27.3 cm)
Cooley Cardiovascular Clamp is ideally suited for use in cardiothoracic surgical procedures that require temporary occultation of the iliac artery. This instrument comes equipped with fully curved jaws making it particularly well suited for use in clamping vessels close to the diameter of the iliac vessels. The scissor grip handles and the ratcheting mechanism for keeping the clamp in place allows for this clamp to stay securely in place through the surgical procedure but is gentle enough to keep from injuring the vessel walls.
Cooley Anastomosis Clamp
Anastomosis Clamp
jaws calibrated at 5.0 mm intervals, 6-1/2" (16.5 cm)
Cooley Anastomosis Clamp is designed for use in cardiothoracic surgical procedures in which an anastomotic connection is to be formed between two vessels and blood flow needs to be reduce significantly via clamping. This instrument features jaws that are calibrated at 5 mm intervals making them ideally suited to give accurate measurement information during a surgical procedures. Additionally, this clamp features a slightly looped, u-shaped clamp to provide optimal gripping capacity but also maintaining that hold consistently throughout the procedure.
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp
Cleveland Clinic Renal Clamp is a specialized piece of equipment designed for optimal use in cardiothoracic surgical procedures. This clamp is designed for use as a renal clamp to block or reduce blood flow through the renal vessels going to and from the kidney. To accommodate the positioning of these vessels this instrument comes with a significant angle to the jaws making access to the renal vasculature easier. This instrument is available angled either to the left or the right and also comes in either small or large jaws to accommodate a number of different patients sizes.
Reviews
There are no reviews yet.